Source smarter with
Leverage AI to find the perfect product match in seconds
Matches from over 100 million products with precision
Handles queries 3 times as complex in half the time
Verifies and cross-validates product information
Get the app
Get the Alibaba.com app
Find products, communicate with suppliers, and manage and pay for your orders with the Alibaba.com app anytime, anywhere.
Learn more

Cw 5000 chiller

(657 products available)

New Design <strong>CW</strong>-<strong>5000</strong> Laser <strong>Chiller</strong> Made in China
New Design <strong>CW</strong>-<strong>5000</strong> Laser <strong>Chiller</strong> Made in China
New Design <strong>CW</strong>-<strong>5000</strong> Laser <strong>Chiller</strong> Made in China
New Design <strong>CW</strong>-<strong>5000</strong> Laser <strong>Chiller</strong> Made in China
New Design <strong>CW</strong>-<strong>5000</strong> Laser <strong>Chiller</strong> Made in China
New Design <strong>CW</strong>-<strong>5000</strong> Laser <strong>Chiller</strong> Made in China

New Design CW-5000 Laser Chiller Made in China

Ready to Ship
$260.00 - 300.00
Min. Order: 2 sets
Shipping per piece: $211.46
15 yrsCNSupplier
0.0/5.0·0 reviews·"received on time"
Theater <strong>Chiller</strong> Home Water / Air Cooled <strong>Chillers</strong>
Theater <strong>Chiller</strong> Home Water / Air Cooled <strong>Chillers</strong>
Theater <strong>Chiller</strong> Home Water / Air Cooled <strong>Chillers</strong>
Theater <strong>Chiller</strong> Home Water / Air Cooled <strong>Chillers</strong>
Theater <strong>Chiller</strong> Home Water / Air Cooled <strong>Chillers</strong>
Theater <strong>Chiller</strong> Home Water / Air Cooled <strong>Chillers</strong>

Theater Chiller Home Water / Air Cooled Chillers

Ready to Ship
$5,000.00 - 6,000.00
Min. Order: 1 piece
Shipping per piece: $300.00
9 yrsCNSupplier
5.0/5.0·2 reviews·"fast delivery"

About cw 5000 chiller

Types of CW 5000 chillers

The term "CW 5000 chiller" refers to a specific model of air-cooled industrial water chiller with a 5,000 BTU/h cooling capacity. Some types of chillers based on their cooling method are as follows:

  • Air-Cooled Chillers:

  • Water-Cooled Industrial Chillers:

    An industrial refrigeration system provides chillers for factories, large-scale commercial establishments, and complexes. While water-cooled chillers are frequently used in residential settings, they may also be suitable options for industrial facilities depending on the specific requirements at hand. Water-cooled chiller systems employ a cooling tower and water as the medium for removing heat from the refrigerant during the cooling process. Because water-cooled chillers use a cooling tower to dissipate heat into the atmosphere, they typically require less electrical power compared to air-cooled chillers that rely on ambient air to remove heat. This enables water-cooled chillers to achieve higher cooling capacities, making them better suited for industrial applications where greater refrigeration needs exist. Additionally, water-cooled chillers tend to operate more quietly since the frantic movement of air is not part of their heat-exchange mechanism. Water-cooled chillers generally feature centralized systems with large-scale vapor-compression refrigeration machines such as screw or centrifugal compressors.

  • Modular Chillers:

    An industrial modular chiller is a type of refrigeration unit commonly used for commercial cooling applications. Modular chillers are characterized by their ability to be easily disassembled into smaller, more manageable parts. Unlike traditional large-scale chillers that come in one solid piece and may be difficult to transport, modular chillers break down into individual modules or sections. This makes it simpler to move the refrigeration units from one location to another as needed. Additionally, the modular design allows for easier installation and setup of the chillers in their final positions. Once put into place, the separate components can be pieced together to form the complete chiller system. The flexibility afforded by the modular construction facilitates not only transportation but also installation, maintenance and repair of industrial cooling equipment.

Some chillers are determined based on the specific needs and applications.

Specification & Maintenance

Specifications may differ depending on the manufacturer. Some of the basic CW 5000 chiller specs include the following:

  • Type: An air-cooled chiller.
  • Temperature range: Operates within the temperature range of 7 to 35 degrees Celsius.
  • Rated cooling capacity: 5,000 calories/hour, equivalent to approximately 2.09 kW.
  • Working Environment: The CW-5000 chiller functions properly in ambient temperatures not exceeding 40°C. Additionally, it should be positioned in a setting free from direct exposure to sunlight and at a distance greater than 1m from other objects, thereby ensuring adequate air circulation.
  • Power supply: single-phase AC power of 220V.
  • Pump flow rate: The CW-5000 chiller is outfitted with a circulating pump whose flow rate may range from 10 to 20 liters per minute (LPM), depending on the specific model and configuration. This pump is responsible for the circulation of the coolant, thus ensuring the comprehensive and uniform dissemination of thermal energy within the system.
  • Noise level: 55-65dB(A) when operating.
  • Expansion tank capacity: The CW-5000 chiller is equipped with an expansion tank boasting an approximate capacity of 2 liters. This component has a pivotal function, serving to accommodate variations in volume induced by fluctuations in temperature during the coolant's circulation process.
  • Refrigerant: The CW-5000 chiller employs a refrigerant, such as R-134a, R-12, or R-22. The specific type of refrigerant utilized may differ according to various manufacturers and models, and each type possesses distinct characteristics and features.

To keep the CW 5000 water chiller running smoothly, it is essential to do a regular maintenance schedule. Some of the maintenance tips include:

  • Regular Cleaning: It's important to clean the exterior surfaces of the chiller and the condenser coil regularly. This helps get rid of dust, dirt, and debris that may have built up over time. Adhering to this practice not only optimizes the cooling effect of the chiller but also contributes to energy savings.
  • Maintenance of the coolant: The coolant in the CW 5000 chiller should always be at the recommended level. Regular inspection should be done to check for any leaks that may occur within the system and promptly address them, if any. Maintaining the proper level of coolant helps ensure efficient cooling performance and prevents overheating.
  • Inspection of the pump: The circulating pump should be inspected regularly to ensure it is working properly and there are no leaks. The flow rate should also be checked on a regular basis and any clogs or abnormalities should be addressed with assistance from a professional technician.
  • Electrical connections: To ensure dependable operation and safety, regular inspection of the chiller's electrical connections should be performed. Loose connections, wear, or damage should be checked and promptly rectified if any issues are identified to ensure a secure and dependable operational condition.
  • Chiller Fan: The cooling fan of the chiller should be checked regularly to make sure it is functioning properly. The connection and operating status should be inspected, ensuring that it works normally and provides adequate airflow for heat dissipation. Should any problem occur, it's important to fix it as soon as possible to ensure the chiller works well.

Scenario of CW 5000 chillers

The CW 5000 chiller has many usage scenarios in different industries. Here are some typical application examples.

  • Cooling laser equipment

    Many types of lasers use the CW 5000 chiller for their cooling system. Laser cutting, engraving, and marking machines generally work with in high-temperature environments. If they are not professionally designed, laser tubes can easily distort and affect the quality of laser beams. Therefore, it is necessary to use a chill to control their temperature to ensure a stable beam output. The same thing applies to laser machines used for tattooing or mole removal on the skin.

  • Plastics Chilling Keeps Products Flexible

    Plastic products start their lives as hard-to-process raw materials. Even though they remain rough, plastic manufacturers use chillers to cool them during the manufacturing process. By applying Cw 5000 chillers at strategic points in production lines, plastics become easy to mold into various shapes and forms without any complications or delays.

    Normally, plastics need to be very cold before being machined or cut. Moreover, cooling plastics with chillers will allow items made of plastic to be more durable, flexible, and long-lasting. Without chillers, many plastic products would easily break or wear out over time. This is because the plastics were not properly cooled during production. With the help of chillers, plastics can be cooled quickly and efficiently, making the entire manufacturing process smoother and faster.

  • Medical and Pharmaceutical Cooling Systems

    The pharmaceutical industry has high demands for temperature control. Devices and machines used to produce drugs need precise temperature management to maintain the quality of medications. Furthermore, medical equipment must be kept at specific temperatures for optimal performance and reliability. The same applies to food and beverage industries where strict temperature regulations exist. Therefore, the CW chiller's ability to chill quickly and efficiently makes it an ideal choice for these industries' machines and devices that require constant cooling to function properly. Its effectiveness in cooling swiftly sets it apart as a preferred cooling system in various sectors that demand precision in temperature control.

  • Cool engraving machine

    An engraving machine, just like laser cutting machines, is generally cooled by a CW 5000 chiller in order to prevent the machine from overheating and ensure that it works effectively. Without the chiller, the engraving machine could become too hot to function properly or safely.

How to Choose CW 5000 Chillers

  • Application Demand:

    Users should consider the application demand and usage scenarios, including the type of equipment to be cool, the volume of heat to be removed, the ambient temperature, the desired coolant temperature, etc. Ensure the CW 5000's refrigerating power and operating temperature range meet the cooling needs of the equipment.

  • System Performance:

    Users should compare the cooling capacity, power consumption, COP (cooling power ratio), noise level, and other parameters of different models to choose a CW 5000 chiller with good performance. For example, a chiller with a higher COP can be more energy-saving and economical.

  • Reliable Design:

    Users should choose a reliable design and quality manufacturing CW 5000 chiller, including the quality of refrigeration components (compressor, condenser, evaporator, expansion valve, etc.), electrical control system, coolant leakage protection and other aspects.

  • Flexible Configuration:

    Some chillers may offer some optional configurations, such as a different type of condenser (air-cooled, water-cooled), different pump power and flow rates, different types and specifications of tanks, and more. Users should choose the configuration that best suits their needs.

  • Brand and Service:

    Choosing a reputable brand can ensure the quality of the product and provide good after-sales service. Users may compare products of different brands, read user reviews, and refer to relevant brand ratings to choose a suitable chiller.

CW 5000 chiller Q&A

Q1: What type of refrigerant is used in a CW 5000 chiller?

A1: The CW 5000 coolers typically use environmentally-friendly refrigerants such as R134a or R404a, which have low ozone depletion potential and good cooling performance.

Q2: How does a CW 5000 chiller compare with an air conditioner?

A2: While a CW 5000 chiller and an air conditioner both cool, their applications differ. Chillers are suitable for industrial processes or cooling large spaces. Air conditioners are ideal for residential or commercial heating and cooling. Additionally, a chiller uses refrigerant-based systems that convert heat into cool. An air conditioner may utilize different systems such as vapor-compression or absorption.

Q3: Can someone connect multiple CW 5000 chillers?

A3: It is possible to connect multiple CW 5000 chillers in parallel to increase the overall cooling capacity.

Q4: What is the pump type used in a CW 5000 chiller?

A4: The CW 5000 chiller uses a centrifugal pump, which is widely used in industrial cooling systems due to its good flow characteristics.

Q5: How long does a CW 5000 chiller last?

A5: With regular maintenance, a CW 5000 chiller can last 10-15 years or longer.